Key
Specifications/Special Features:
Feature:
■
32 Open-Collector output channels
■
32 Optical isolated digital input channels
■
Built-in internal DC-DC conveter for detecting dry
conatcs
■
on-board software programmable digital debounce
■
Software
programmable Interrupt handling for 16 input channels
Specification:
■ Open-collector (NPN)
Outputs
Channel:
32 open-collector output channels
Output
driver: M52522P
Load
current: 130mA (Max) per channel
Load
Voltage: 30VDC
■ Isolated inputs
Channel:
32 optically isolated digital input channels
Type:opto-isolated
(PC-814)
Input
voltage: DC 5-24V (0- 1KHz)
Input
impedance: 4.7 Kohm
Response
time: 20u Sec
Interrupt:
16 channels , Pos./neg. edge interrupt
Debounce
time: Digital debounce time from 2 mSec to 40 mSec
Isolated:
1500v channel-channel / channel - Ground
■
Isolated inputs
Input
channel : 8 opto-isolated channels
Type:
opto-isolation channels
Input
voltage: DC 5-24V (0-1KHZ)
Input
impedance: 4.7k ohm
Response
time: 20u sec
Isolated
: 500v channel-channel / channel - Ground
■
Software Toolkit (DLL, ACtivex) for Windows 98/2000/NT/XP
■
Software Toolkit for Labview, Intouch
■
Power requirements: +5V 500mA (typical)
■
Operation Temp. :0° C~50° C
■
Storage Temp. : -20° C~70° C
■
Humidity:
0 to 90% none-condensing
|